UPS COVER PS 40K
COVER Online Double-Conversion uninterruptible power supply, with a capacity of 40kVA/40kW. Power modules in 3U size, for mounting in 19' rack cabinet. Freely configurable 3:3/3:1/1:1/1:3 phase configuration.
11-PS-40
BACKUP TIME
EBM PS | Load | Backup time [min] |
PS 40K | ||
UPS +2xEBMs (40x9Ah) | 100% | - |
75% | - | |
50% | 4 | |
25% | 11 | |
UPS + 4xEBMs (2x40x9Ah) | 100% | 4 |
75% | 6 | |
50% | 11 | |
25% | 29 | |
UPS + 6xEBMs (3x40x9Ah) | 100% | 8 |
75% | 11 | |
50% | 20 | |
25% | 48.5 | |
UPS + 8xEBMSs (4x40x9Ah) | 100% | 11 |
75% | 17 | |
50% | 29 | |
25% | 66 |
TECHNICAL SPECIFICATIONS
Model | PS 40K |
Power factor | 40kVA / 40kW |
Phases In/Out | 3:3 |
Design | Rack/Tower |
Input | |
Nominal voltage | 220 / 230 / 240 VAC | 380 / 400 / 415 Vac |
Voltage range | 100 ÷ 160 VAC @ load 50% - 100%, 160 ÷ 300 VAC @ load 100% 174 ÷ 278 VAC @ load 50% - 100%, 278 ÷ 522 VAC @ load 100% |
Nominal frequency | 50 / 60Hz |
Frequency range | 45 ÷ 65 Hz |
THDi | <3% |
Input power factor | ≥0,99 |
Output | |
Nominal voltage | 220 / 230 / 240 VAC | 380 / 400 / 415 Vac |
Power factor | 1,0 |
Voltage regulation statis/dynamic | ±1% / ±3% |
Nominal frequency | 50 / 60 ± 0,1 Hz |
Overload caability | 105% no limit, 125% - 10 min., 150% - 30 s., >150% - 500 ms |
Efficiency in OnLine mode | 96% |
Efficiency in ECO mode | 98% |
Crest factor | 3:1 |
Switching time | 0ms |
Batteries | |
Cold start | yes |
Type of batteries | VRLA, AGM, gel |
Batteries range | 32 - 40 pcs x 12V |
Max charging curent | 13A |
Charging type | 3 – 8 hours up to 90% capacity (configurable) |
Charging cycle | According to DIN 41773 with automatic charging shutdown according to current and voltage criteria, with time control. |
Dimensions and weights | |
Dimensions (S x G x W) | 440 x 750 x 132 (3U) |
Weight w/o batteries | 38,0 kg |
Signaling and communication ports | |
Operating status indicator | LCD + audible alarm |
Communication | USB, RS232, RS485, Dry in/out, EMBS, EPO, slot SNMP |
Environmental conditions | |
Noise level | <65 dB @ load 100% |
Operating temperature for UPS | 0°C ÷ 40°C |
Recommended operating temperature | 15 °C ÷ 25 °C |
Storage temperature | -20°C ÷ 40°C |
Humidity | 0 ÷ 95% (non-condensing) |
Cerifications | |
Interference immunity | EN 62040-2:2018, EN 61000-3-2:2019, EN 61000-3-3:2013+A1:2019 |
Safety | EN 62040-1:2019, EN 62040-1-2:2003, 62040-3:2001, CE |
Optional accesories | |
- SNMP card | |
- AS 400 mini (dry-contact) card | |
- Environmental sensor (EMD) | |
- Remote Emergency Power Off button | |
- External maintenance bypass | |
- Remote LCD panel | |
Due to constant product improvement all specifications are subject to change without notice.