UPS COVER BASIC 1K

COVER Online Double-Conversion uninterruptible power supply, 1kVA/0.9kW. Plug@Play. Tower cabinet (without batteries). 1:1 phase configuration.

11-BASI-0010

Diesel generator set ESE 17 TBI

CHARACTERISTICS

  • The ESE 17 TBI diesel generator produced by Endress Group Romania under the Zenessis brand is equipped with BAUDOUIN 4M06G20/5 engine, Stamford SOL1-P / Strathon ECO-17KW alternator and INTELI LITE AMF 25 control system, which ensures the starting of the generator, the control of the parameters, in manual or automatic system. The generator can be supplied with remote control and monitoring as well as other options. Zenessis power generators are guaranteed for 60 months, up to 3000 operating hours.
  • Command & control panel with measurement & metal control devices, protection class IP54
  • Static battery charger
  • Dynamic battery charging alternator
  • Controlled thermostat heater for coolant
  • Oversized start battery
  • Emergency stop button
  • Chassis with fuel tank sized for 8hrs of autonomy
  • Vibration dampers
  • Fuel level measuring device
  • Electrical lines protected with tubing & gland
  • Residential silencer
  • Access doors on all 4 sides provided with locks
  • Crane or forklift handling system
  • Flameproof and soundproof insulation
  • Protective pads
  • Metal hinges

ENGINE

Specifications Value Baudouin diesel engine
Model 4M06G20/5

2click car

Number of cylinders 6 in linie
Induction system Natural aspiration
Cooling system With water
Maximum standby power (kWm) 20
Speed (rpm) 1500 rpm
Cylinder 2.3 (I)
Bore & Stroke (mm) 89 x 92 mm
Compression factor 17.5 : 1
Regulator Mechanic
Total oil capacity (l) 9.5 (I)
Cooling agent capacity 5 (l)
Fuel consumption at 100% load (l / h) 4,1 (l / h)

STANDARD FEATURES

Specifications Value Alternator
Model Stamford SOL1-P / Strathon ECO-17KW

2click car

Frequency (Hz) 50 Hz
Concept Brushless, 4 poles
Phases 3
Voltage (V) 400 / 230 V
Protection class H
Excitation system Electronic
Performance 93%
Protection IP23
Certification test test EN 10204:2001

CONTROL PANEL

  • Control panel made in metal box, IP54 degree, with lock. The control panel is equipped with the ComAp AMF25 control module, with the possibility of starting and stopping the generator, both in automatic and in electric mode. The control panel monitors the power grid and can command and control the ATS panel (automatic transfer switch).
  • The command and control panel is mounted inside the casing, in a metal box with IP 54, equipped with a viewing glass, equipped with:
  • -ComAp AMF 25 command module
  • -Static battery charger
  • -Emergency stop button & circuit breaker fuses control
  • -Overcurrent differential protection
  • -Protection relays

CONTROL PANEL STANDARD SPECIFICATIONS

  • 1. Left button
  • 2. Right button
  • 3. Horn Reset button
  • 4. Fault Reset button
  • 5. Up button
  • 6. Page button
  • 7. Down button
  • 8. Enter button
  • 9. Start button
  • 10. Stop button
  • 11. GCB button. Works in MAN and TEST modes only
  • 12. MCB button. Works in MAN and TEST modes only
  • 13. Generator status indicator
  • 14. GCB On. Green LEDs are on if GCB is closed and Gen-set is healthy
  • 15. Load
  • 16. Graphic B/W display, 132 x 64 pixeli
  • 17. Mains status indicator
  • 18. MCB On. The green LEDs are “on” when the MCB is closed and the network is within the preset parameters.

2click car

COMMAND MODULE STANDARD SPECIFICATIONS

  • Microprocessor control
  • 132 x 64 pixeli LCD display
  • Programming on front panel as well as through PC software
  • Control buttons and soft touch navigation
  • Remote communication via USB or with optional modules via RS232, RS485, Ethernet or SMS
  • Store 180 events with date and time
  • Maintenance programming 3 levels
  • Engine heater control –Optional

COMMAND MODULE CONFIGURATION

  • 1. ComAp AMF25 command module
  • 2. Circuit Breaker protection
  • 3. Locks
  • 4. Alarm
  • 5. START button ON / OFF
  • 6. Hinges
  • 7. Maintenance schedule
  • 8. Metal box

2click car

Engine – engine speed; oil pressure; coolant temperature; running time; battery voltage; maintenance data.
Alternator – voltage (L – L, L – N); current (L1 – L2 – L3); frequency; kW; Pf; kVAr; kWh,kVAh, kVarh; phase sequence.
Main network – voltage (L – L, L – N); frequency, mains ready; mains off; generator set ready, generator set disconnected, active power kW, apparent power kVA, reactive power kVA r, power factor, phase sequence.
Warning – battery faulty charging, low battery voltage, fail to stop, low fuel level, overload, phase reversing, speed sensor failure.
Alarms – low oil pressure, high engine temperature, under / over voltage, under / overfrequency, under / overvoltage, ECU fault -optional.
Status displays – missed start, emergency stop, low oil pressure, high engine temperature, under / overspeed, under / overfrequency, under / overvoltage, oil sensor, phase rotation, overload, overcurrent group, phase reversal.

STATIC BATTERY CHARGER:

Made with TSD technology, with high efficiency. Protected for short- circuit currents, it can be used as a current source, input voltage 196-264 V, output voltage 27.6 V / 5A or 13.8 V / 5A.

STANDARDS

Electrical safety / EMC, BS EN 60950; BS EN 60950 – 6 – 2 EMC; BS EN 61000 – 6 – 4 EMC.

HOUSING

  • Made of galvanized steel, electrostatically painted, acoustically insulated
  • Modular design with interior access doors on all sides of the generator
  • Residential type muffler mounted inside the housing
  • The housing are designed to optimize the cooling of the engine and alternator assembly, and can be mounted outdoors, providing protection against weathering and low noise levels.
  • 1. Command module
  • 2. View window
  • 3. Access door for control module
  • 4. Points for crane lifting (optional)
  • 5. Spaces for handling with the forklift
  • 6. Engine and alternator access door
  • 7. Air intake grills
  • 8. Handles provided with locks
  • 9. Fuel supply bus (optional)
  • 10. „Sleigh chassis” fitted with lifting/pulling holes
  • 11. Emergency button
  • 12. Exhaust Gas Valve
  • 13. Cable access space
  • 14. Hot air outlet grills
  • 15. Protective pads

2click car

DEMENSIONS AND WEIGHT OF OPEN GENSET

  • Sizes (length x width x height) (mm)
  • Weight (kg)
  • Fuel tank capacity (liters)
  • 1870 x 860 x 1055
  • 550
  • 50

DEMENSIONS AND WEIGHT OF THE CLOSED GENSET

  • Sizes (length x width x height) (mm)
  • Weight (kg)
  • Fuel tank capacity (liters)
  • 1870 x 860 x 1385
  • 740
  • 50
Apparent power [kVA]
1
Active power [kW]
0,9
Technology:
VFI-SS-111 (OnLine DoubleConversion)
Phase In/Out:
1:1
Output PF:
0,9
Max internal batteries
2